The Importance of Operating with Proper Furnace DraftThe Importance of Operating with Proper Furnace DraftThe Importance of Operating with Proper Furnace DraftThe Importance of Operating with Proper Furnace Draft
  • Home
  • Services
    • Services Overview
    • Technical Training
    • Plant Engineering
    • Technology Transfer
    • Short Course Catalog
  • Industries Served
    • Power Generation
    • District Energy
    • Transmission & Distribution
    • Pulp and Paper
    • Water and Wastewater Treatment
    • Beverage
    • Heavy Industry
  • Who We Are
    • Our Team
    • Experience
    • Careers
  • Blog
  • Contact us
✕
A graphical representation of high versus low fidelity graphics
Fidelity: Low vs. High Fidelity Graphics
August 7, 2020
Two Oil and Gas Workers in front of Combined Cycle Plant piping
Challenges Facing the Power Industry
September 17, 2020
Show all

The Importance of Operating with Proper Furnace Draft

Published by James Wiggins at August 26, 2020
Furnace Draft wider shot

Most power plant boilers have balanced draft furnaces. This means there is a fan (or fans) that supplies combustion air to the boiler furnace, known as a forced draft fan, and another fan that pulls the exhaust gases (flue gas) from the boiler furnace1, known as an induced draft Fan.  These fans work together to maintain pressure (or draft) in the furnace slightly less than atmospheric pressure, usually with a furnace pressure setpoint of about -0.5 inwc.  It is important that operators monitor furnace draft during operation of their power plant boilers, understand the importance of proper furnace draft, and know how to adjust furnace draft during varying plant operating states.

Protecting Personnel and Safety

Serious problems can result from the operation of a boiler with positive pressure.  Maintaining furnace pressure NEGATIVE is essential so that air from the boiler building/atmosphere leaks into the flue gas ducting and boiler setting, referred to as “tramp air”, instead of flue gas leaking out of the boiler and ducting into the spaces occupied by personnel and equipment.  Boilers with pressurized furnaces often have leakage of flue gas from the boiler setting into the plant that makes working around the boiler very difficult because of the health effects of breathing hot flue gas and (for coal-fired boilers) fly ash.

Corrosion

Another problem with pressurized furnaces is corrosion of the boiler casing and other components from acids of sulfur that are created when the temperature of the leaking flue gas falls below the acid dew point2.  Most fuels contain some amount of sulfur and when burned in the boiler furnace produce oxides of sulfur (SOx) in the exhaust gases leaving the boiler.  The majority of SOx in the flue gas is SO2 but there is also SO3 (typically 2-4%)3.  If the flue gas temperature is low enough (below the acid dew point), the SO3 will combine with water (H2O) to form sulphuric acid.

Sulphuric acid is highly corrosive and damages power plant equipment, especially air heaters and economizers.  To prevent sulfuric acid from forming, flue gas temperatures are always maintained above the acid dew point.  However, if the draft is a positive pressure and flue gas leaks from the furnace and flue gas ducting, sulphuric acid will be formed around the leaks because it will be entering a cooler and more humid environment.  Those leaks will then continue to enlarge and worsen as the sulphuric acid that is formed around the leak causes more corrosion in the area.

Too Far Negative

Given the desirability of having a negative pressure in the furnace, some operators “overdo” it by maintaining a lower (more negative) pressure than necessary.  It is possible to cause significant inefficiency by operation with too low pressure in the boiler for several reasons.  One, a significant increase in auxiliary power consumption can result from too low a furnace pressure.  The auxiliary power required for the operation of the induced draft fan(s) pulling gases from the boiler furnace increases as the furnace pressure falls for a given flow of flue gas.  The increased fan power is caused by the greater head being developed by the fan and because lower pressure in the boiler causes more tramp air in-leakage; thus more flue gas that has to be handled by the fan.

Another effect of operating with too low pressure in the furnace is less direct.  The lower pressure in the furnace causes increased air leakage into the boiler.  When this tramp air mixes with the flue gas, the percentage of oxygen in the flue gas (excess air) goes up.  This is true even though tramp air does little if anything (depending on the leakage locations) to help support combustion.  For most boilers, when the combustion air control loop detects an increase in excess air in the flue gas, it responds by reducing the combustion airflow to the furnace.  The result is too little excess air and thus higher unburned fuel losses4.

Given the impacts of operating with correct furnace pressure, operators should monitor furnace pressure closely.  In the event that the furnace pressure is higher or lower than the setpoint of -0.5 inwc, the problem should be reported and corrected as soon as possible.

Summary

Understanding the furnace draft and the importance of maintaining draft slightly negative is critical to power plant operators’ ability to safely and efficiently operate their boilers.  Management should ensure their operators are professionally trained on furnace draft, site-specific control systems, and how these control systems are utilized to maintain furnace draft slightly negative during varying plant operating states.

 

  1. https://cache.industry.siemens.com/dl/files/060/51436060/att_107150/v1/AD353-106r3.pdf
  2. https://cdn.website-editor.net/57b3a6d8dd784e4884b30c9fc529f0e0/files/uploaded/1%202017%20EPRI%20HEAT%20RATE%20Conf-Impact%20of%20Air%20In-Leakage%20on%20Unit%20Reliability%20%26%20Operating%20Costs.pdf
  3. https://www.digitalrefining.com/article/1002333/flue-gas-heat-recovery-through-the-acid-dew-point#.X0Uq_uhKiUk
  4. https://www.airflowsciences.com/services/field-testing/inleakage
James Wiggins
James Wiggins
James Wiggins is a Vice President at FCS. After nearly a decade as a US Navy operator and mechanic, He shifted focus to providing operational readiness services and training to energy-producing plants and process facilities. With 15+ years of industry-related experience, he possesses a wealth of knowledge and is passionate about providing value to his customers.

Related posts

October 31, 2022

MWh Generation Cost Factors


Read more
October 7, 2022

Fossil Fuel Prices Over Time


Read more
September 12, 2022

Microgrid and District Energy: The Future of Electricity?


Read more

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Recent Blog Posts

  • 0
    Liquid Glass: The characteristics of Laminar Flow
    January 20, 2023
  • 0
    Hybrid Power Plants
    January 5, 2023
  • 0
    Bridging the Skills Gap: Fixing the staffing problem in power generation.
    December 13, 2022

Fossil Consulting Services, Inc.

6325 Woodside Court, Suite 222
Columbia, Maryland 21046
Telephone: (410) 312-6240
Email: FCS@FossilConsulting.com

NEW FCS Logo_White
© 2022 Fossil Consulting Services, Inc. All Rights Reserved.