Cooling Tower Factors: Temperature, Range & ApproachCooling Tower Factors: Temperature, Range & ApproachCooling Tower Factors: Temperature, Range & ApproachCooling Tower Factors: Temperature, Range & Approach
  • Home
  • Services
    • Services Overview
    • Technical Training
    • Plant Engineering
    • Technology Transfer
    • Short Course Catalog
  • Industries Served
    • Power Generation
    • District Energy
    • Transmission & Distribution
    • Pulp and Paper
    • Water and Wastewater Treatment
    • Beverage
    • Heavy Industry
  • Who We Are
    • Our Team
    • Experience
    • Careers
  • Blog
  • Contact us
✕
Combined Cycle Plant with red and yellow piping and blue sky
Issues with Training and Qualification Jobs for Combined Cycle Plants
June 1, 2018
Silhouette of Engineers Shaking Hands in front of High Voltage Power Lines
Emissions Targets and De-Carbonization Drive
June 12, 2018
Show all

Cooling Tower Factors: Temperature, Range & Approach

Published by Jason Enge at June 4, 2018
Exterior view of cooling tower building

When asked, most operators will provide the purpose of a cooling tower: to reduce the temperature of water to the lowest practicable point.  Pressed on the topic, however, most could not explain how the ambient temperatures and humidity affect the performance of the tower.  If the temperature was 70°F outside, the average operator might tell you that they would expect their CT to put out 70°F water.  But is this always true?  Is the tower operating efficiently?

Two important (and often misunderstood) factors that describe cooling tower performance are range and approach.  To understand these terms, one must understand the difference between “dry bulb temperature” and “wet bulb temperature.”

Temperature

Ask a friend to define temperature and you will likely hear something along the lines of “how hot or cold something is;” and this definition is good enough to get most of us through the day.  Regarding ambient temperature, most people perceive it to be what the thermometer reads or what the television weatherperson tells us.  But the television weatherperson always throws in ambiguous qualifiers: humidity, heat index, dew point.  These terms play an important part not only in how it feels outside but in how well cooling towers perform.

While that thermometer on the front porch does a good job of telling you one thing: dry bulb temperature, it doesn’t tell you how comfortable that temperature is right now.  And, we have all heard the people in Phoenix say, “sure it’s 110°F, but it’s a dry heat.”  After you roll your eyes and stop and think about it – what does that mean?

A typical outdoor thermometer is showing you what is referred to as the “dry bulb temperature.”  It does not take into account the relative humidity in the air.  Relative humidity is an expression of how much moisture is actually in the air compared to how much there could be at this temperature.  If the humidity is 100%, the air is completely saturated with water and no evaporation is possible.  This means that neither your facility’s cooling tower nor your body perspiring will enjoy the effects of evaporative cooling.  You will just sit there and sweat and your cooling tower will underperform one located in lower humidity at the same temperature.

To measure the effects of both the temperature and humidity together, we use a psychometric chart.  These charts combine the effects of humidity and temperature to calculate the “wet bulb temperature.”  The wet bulb temperature describes the effects of evaporative cooling on both your body and on cooling towers.  Using these charts, it is easy to see how a 95°F/30% humidity day in Phoenix can feel downright comfortable, while the 80°F/70% day in Atlanta is uncomfortable – you just don’t get the same evaporative cooling effect in Atlanta.  This is why most facilities measure ambient temperature and humidity.

Approach

Cooling tower approach is the difference in temperature of the water entering the basin (cold) and the wet bulb temperature.  For the purpose of tower design, a tower with a smaller approach (small delta between basin water temperature and wet bulb temperature) is considered superior.  Modern towers commonly have approach temperatures as low as 5°F.  While it is possible to have a smaller approach, it becomes cost-prohibitive since the size of the tower grows exponentially as approach lowers, which in turn requires more pumps and fans.  This leads to more auxiliary power usage and diminishing returns.

In a mechanical draft tower, the only variables that change approach are wet bulb temperature and heat load (the amount of heat removed by the tower).  If your facility has variable speed cooling tower fans, approach can be reduced by increasing fan speed and therefore taking advantage of more evaporative cooling.  If fan speed and heat load are maintained constant for a given wet bulb temperature, approach is constant.

Range

Put simply, range is the difference between the temperature of water entering the cooling tower and leaving the cooling tower.  It is determined by the heat load on the tower and the water circulation rate.  If pump speed is constant and heat loads are constant, the tower range does not change.  This means that for a clean, properly functioning tower, wet bulb temperature does not affect cooling tower range.  Consequently, in practice, for a given water flowrate and heat load, if wet bulb temperature increases, tower inlet and outlet temperature increase proportionally.  The result is an unchanged range.

Typically, cooling towers are designed to cool a specified maximum flowrate of water from one temperature to another at an exact wet bulb temperature.  For example, a designed tower may be guaranteed to cool 10,000 gpm of water from 95°F to 80°F at 75°F wet bulb temperature.  In this case, the range is 15°F and the approach is 5°F.  These design calculations are always done using average wet bulb temperatures at the site where the tower will be installed to ensure performance guarantees are met.

Summary

With an understanding of wet bulb temperature, range and approach, the operator should be able to understand the lowest theoretical basin temperature for the current temperature and humidity.  Using the cooling tower range, they can estimate how efficiently the process is functioning in comparison to cooling tower design.  Armed with their newfound knowledge of these properties, the operator can efficiently stage pumps and fans without trying to squeeze out one more degree of approach that is simply not physically possible.

 

Jason Enge
Jason Enge
Jason Enge is President of FCS and licensed First Grade Engineer who has been with FCS for ten years. Additionally, he holds a BS in Business Management. Previously, Jason spent 20 years as a nuclear power plant operator/mechanic and lead trainer in the US Navy, including a tour at the US Naval Academy. He specializes in operation and maintenance of steam plants, water treatment plants, district energy plants, and industrial heating and chiller plants. He has authored and instructed courses on several types of plants and environmental controls systems.

Related posts

October 31, 2022

MWh Generation Cost Factors


Read more
October 7, 2022

Fossil Fuel Prices Over Time


Read more
September 12, 2022

Microgrid and District Energy: The Future of Electricity?


Read more

4 Comments

  1. ctp soğutma kuleleri says:
    June 13, 2020 at 8:44 am

    nice article, thanks

    Reply
  2. Greta James says:
    June 16, 2020 at 12:40 pm

    Thank you so much for pointing out that the temperature range for the tower depends on the water temperature and circulation rate. It sounds like the wet-bulb takes on a good amount of temperature control. I wonder if it malfunctions or breaks very often. My brother is thinking that he will need a cooling tower for his material production line, and I want to help him make sure that he will have all the products and inspections needed to keep it operational.

    Reply
  3. Mable Buchar says:
    April 7, 2021 at 10:58 pm

    Thank you so much

    Reply
  4. Richard Jarvis says:
    June 21, 2022 at 12:40 pm

    Thank you Jason. You made it clear and understandable.

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Recent Blog Posts

  • 0
    Liquid Glass: The characteristics of Laminar Flow
    January 20, 2023
  • 0
    Hybrid Power Plants
    January 5, 2023
  • 0
    Bridging the Skills Gap: Fixing the staffing problem in power generation.
    December 13, 2022

Fossil Consulting Services, Inc.

6325 Woodside Court, Suite 222
Columbia, Maryland 21046
Telephone: (410) 312-6240
Email: FCS@FossilConsulting.com

NEW FCS Logo_White
© 2022 Fossil Consulting Services, Inc. All Rights Reserved.